Fabrication of a nanostructure modified sensor for determination of butylated hydroxytoluene as an antioxidant in food samples

Document Type : Original Article

Authors

Abstract

In this research, a carbon paste electrode modified with CdO/CNTs nanocomposite and 1-Butyl-3-methylimidazolium hexafluorophosphate ionic liquid fabricated and was used for determination of butylated hydroxytoluene. CdO/CNTs synthesized by chemical precipitation method and characterized by XRD method. Under optimum condition, the peak currents of square wave voltammograms (SWV) of butylated hydroxytoluene increased linearly with its concentration in the ranges of 0.1–600 μM. The detection limit for butylated hydroxytoluene was 0.06 μM. The modified sensor has been successfully applied for the assay of butylated hydroxytoluene in food samples. In this research, a carbon paste electrode modified with CdO/CNTs nanocomposite and 1-Butyl-3-methylimidazolium hexafluorophosphate ionic liquid fabricated and was used for determination of butylated hydroxytoluene. CdO/CNTs synthesized by chemical precipitation method and characterized by XRD method. Under optimum condition, the peak currents of square wave voltammograms (SWV) of butylated hydroxytoluene increased linearly with its concentration in the ranges of 0.1–600 μM. The detection limit for butylated hydroxytoluene was 0.06 μM. The modified sensor has been successfully applied for the assay of butylated hydroxytoluene in food samples. 

Keywords


[1] J. F. Schabron, L. E. Fenska, Anal. Chem., 52 (1980) 1411.
[2] M. Ding, J. Zou, Food Chem. 131 (2012) 1051.
[3] C. D. Garcıa, P. I. Ortiz, Electroanalysis, 10 (1998) 832.
[4] M. Tomášková, J. Chýlková, V. Jehlička, T. Navrátil, I. Švancara, R. Šelešovská, Fuel, 123 (2014) 107.
[5] M. Asunción Ruiz, P. Sedeń, J.M. Pingarrón, Electroanalysis 6 (1994) 475.
]6[ حسن کریمی مله ، علی پهلوان، رویا صادقی ، سید کمال شیردل، مجله شیمی کاربردی  (اندیشه علوم) سال هفتم، شماره 22 سال 1391 صفحه 49.
[7] A.L. Sanati, H. Karimi-Maleh, M. Abbasghorbani, Journal of Applied Chemistry, 9 (2015) 35.
 
[8] H. Karimi-Maleh, A. FallahShojaei, K. Tabatabaeian, F. Karimi, S. Shakeri, R. Moradi, Biosens. Bioelect. 86 (2016) 879.
[9] N.F. Atta, A. Galal, S.M. Azab, Int. J. Electrochem. Sci., 6 (2011) 5082.
[10] N.F. Atta, A. Galal, A.A. Wassel, A.H. Ibrahim, Int. J. Electrochem. Sci., 7 (2012) 10501.
[11] K.S. Ngai, W.T. Tan, Z. Zainal, R.M. Zawawi, M. Zidan, Int. J. Electrochem. Sci., 8 (2013) 10557.
[12] H.R. Naderi, P. Norouzi, M.R. Ganjali, Appl. Surf. Sci. 366 (2016) 552.
[13] R. Bavandpour, H. Karimi-Maleh, M. Asif, V.K. Gupta, N. Atar, M. Abbasghorbani, J. Mol. Liq. 213 (2016) 369.
[14] T. Tavana, M.A. Khalilzadeh, H. Karimi-Maleh, A.A. Ensafi, H. Beitollahi, D. Zareyee, J. Mol. Liq. 168 (2012) 69.
[15] B. Nikahd, M.A. Khalilzadeh, J. Mol. Liq. 215 (2016) 253.
[16] S. Cheraghi, M.A. Taher, H. Karimi-Maleh, Electroanalysis 28 (2016) 366.
[17] R. Sadeghi, H. Karimi-Maleh, A. Bahari, M. Taghavi, Phys. Chem. Liq., 51 (2013) 704.