Simultaneous electrochemical determination of morphine and phenylephrine using carbon nanotubes/ionic liquid nanocomposite modified carbon-ceramic electrode

Document Type : Original Article

Authors

Abstract

In the present study, carbon ceramic electrode prepared using sol-gel method was modified by multi-walled carbon nanotubes (MWCNT) and the ionic liquid (IL) nanocomposite. The electrode modifying process was performed by depositing the MWCNT/IL suspension on the electrode surface. Electrochemical studies revealed that the IL/MWCNT nanocomposite modified carbon ceramic electrode exhibited high electrocatalysis properties for oxidation of morphine and phenylephrine with respect to the MWCNT/CCE and bare CCE. The obtained results from present study indicate that IL/MWCNT nanocomposite modified carbon ceramic electrode can be applied as an appropriate sensor for the measurement of morphine and phenylephrine using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The linear dynamic ranges and limits of detection for two compounds were obtained. Moreover simultaneous determination of morphine and phenylephrine is possible using this modified electrode and they can be determined without others interferences.

[1] J. R. Stetter, G. J. Maclay. Enabling Technology for MEMS and Nanodevices, WILEY-VCH Verlag GmbH & Co. KgaA. 2008 Chapter 10.
[2] M. Trojanowicz, TrAC Trends in Analytical Chemistry, 25 (2006) 480.
[3] J. Wang, Electroanalysis, 17 (2005) 7.
[4] N. Yang, X. Chen, T. Ren, P. Zhang, D. Yang, Sensors and Actuators B: Chemical,207 (2015) 690.
[5] F.R. Baptista,   S.A. Belhout,   S. Giordani,  S.J. Quinn, Chemical  Society Review, 44 (2015) 4433.
[6] S. Ijima, Nature, 354 (1991) 56.
[7] B. Habibi, MH Pournaghi-Azar, Electrochimica Acta, 55 (2010) 5492.
[8] B. Habibi, M. Jahanbakhshi, M.H. Pournaghi-Azar, Analytical Biochemistry, 411 (2011) 167.
[9] B. Habibi, M. Jahanbakhshi, M.H. Pournaghi-Azar, Electrochemica Acta, 56 (2011) 2888.
[10] R.T. Kachoosangi, G.G. Wildgoose, R.G. Compton, Analytica Chimica Acta, 618 (2008) 54.
[11] K. Sarhangzadeh, R. Mmohamma-Rezaei, M. Jabbri, Analytical Letters, 47 (2014) 134.
[12] N.F. Atta, M.F. El-Kady, A. Galal, Sensors and Actuators. B: Chemical, 141 (2009) 566.
[13] M.G. Galinski, A. Lewandowski, I. Stepniak, Electrochimca Acta, 51 (2006) 5567.
[14] R. Rogers, K. Seddon, Science, 302 (2003) 792.
[15] T. Fukushima, A. Kosaka, Y. Ishimura, T. Yamamoto, T. Takigawa, N. Ishii, T. Aida, Science, 300 (2003) 2072.
[16] A. Abo-Hamad, M. A. AlSaadi, M. Hayyan, I. Juneidi, M.A. Hashim, Electrochimica Acta, 193 (2016) 321.
[17] A. Salimi, R. Hallaj, G.R. Khayatian, Electeroanalysis, 56 (2005) 185.
[18] A. Ensafi, A. Karimi-Maleh , Electroanalysis, 115(2010) 256.
[19] M.J. Galmier, A.M. Frasey, S. Meski, E. Beyssac, J. Pettit, J.M Aiache, C. Lartigue, Biomedical Chromatography, 14 (2000) 202.
[20] J.A. Arancibia, A.J Nepote, G.M. Escandar, A.C. Olivieri, Analytica Chimica Acta, 419(2000) 159.
[21] B. Rezaei, S. Foroughi-Dehnavi, A.A. Ensafi, Ionics, 21(2015) 2969.
[22] Y. Zhu, Z. Zhang, W. Zhao, D. Pang, Sensors and Actuators B: Chemical, 119 (2006) 308.
[23] A.A. Ensafi, M.Izadi, B. Rezaei, H. Karimi-Maleh, Journal of Molecular Liquids, 174 (2012) 42.
[24] E. Afsharmanesh, H. Karimi-Maleh, A. Pahlavan, J. Vahedi, Journal of Molecular Liquids, 181 (2013) 8.
[25] A.A. Ensafi, B. Rezaei, Hassan Krimi-Maleh, Ionics 17 (2011) 659.
[26] A. Navaee, A. Salimi, H.Teymourian, Biosensors and Bioelectronics, 31 (2012) 205.
[27] M.R. Shishehbore, H.R. Zare, D. Nematollahi, Journal of Electroanalytical Chemistry, 665 (2012) 45.
[28] K.-Z. Tang,  L. Liu, Y.-P. Hong, J.-M. Hu,  J.-Q. Zhang,  C.-N. Cao, Journal Applied Electrochemistry, 40 (2010) 1699.
[29] F. Li, J. Song, C. Shan, D. Gao, X. Xu, L. Niu, Biosensors and Bioelectronics, 25 (2010) 1408.
[30] A. Samadi-Maybodi, S.K. Hassani Nejad-Darzi, H. Ilkhani, Analytical Bioanalanalytical Electrochemistry,3 (2011)134.
[31] M.B. Gholivand, G. Malekzadeh, M. Torkashvand, Journal of Electroanalytical Chemistry, 704 (2013) 50.
[32] W. Nogala, A. Celebanska, K. Szot, G. Wittstock, M. Opallo, Electrochimica Acta, 55 (2010) 5719.
[33] A. Salimi, S. Pourbeyram, Talanta, 60 (2003) 205.
[34] O. Lev, Z. Wu, S. Bharathi, V. Glezer, A. Modestov, J. Gun, L. Rabinovich, S. Sampath,  Chemistry of  Material, 9 (1997) 2354.
[35] B. Habibi, M. Abazari, M.H. Pournaghi-Azar ,Colloids and Surfaces B: Biointerfaces, 114 (2014) 89.
[36] B. Habibi, M. Jahanbakhshi Analytical Bioanalanalytical Electrochemistry, 7 (2015) 45.
[37]B. Habibi, M. Jahanbakhshi, M. Abazari, Journal of the Iranian Chemical Society, 11 (2014) 511.
[38] B. Habibi, H. Pezhhan, M.H. Pournaghi-Azar, Microchimica Acta, 169 (2010) 313.
[39] A. Mokhtaria, H. Karimi-Maleh, A.A. Ensafic, H. Beitollahi, Sensors and Actuators B Chemical, 169 (2012) 96.
[40] A.L. Sanati, H. Karimi-Maleh, A. Badiei, P. Biparva, A.A. Ensafi, Materials Science and Engineering C,35 (2014) 379.
[41] J. Wang, R.P. Deo, M. Musameh, Electroanalysis, 15 (2003) 23.
[42] Y. Zhua, Z. Zhang, W. Zhao, D. Pang, Sensors and Actuators B: Chemical, 119 (2006) 308