Electrochemical insulin sensor based on complex tris(1-10, phenanthroline) cobalt (II) and multiwalled carbon nanotubes modified glassy carbon electrode

Document Type : Original Article

Authors

Department of Chemistry, Faculty of Science, Zanjan University, Zanjan, Iran

Abstract

Modification of a glassy carbon electrode with multiwall carbon nanotube and a thin film of polyPoly[Co(Phen)3] was proposed as an electrochemical insulin sensor. For electropolymerization of Poly[Co(Phen)3]2+, 10 cyclic voltammetry were applied with scanning speed 0.5 V/S and range of potential -0.3 and 0.85 V relative to the reference electrode Ag / AgCl in phosphate buffer solution 0.05M, pH=4/7. The modified electrode showed an excellent selectivity and sensitivity toward insulin with a wide linear range 1.67-0.741 and 0.099-.654 µM and a very low detection limit of 8 nM. The proposed method is accurate, simple, cheap and could be used for determination of insulin in real samples such as blood samples.

Keywords

Main Subjects


]1[ S. Ligler,C.R.Taritt, "Optical biosensors"20 (2001) 12.
]2[ X.J. Huang, Y.K. Choi, Chemical sensors based on nanostructured materials, Sensors and Actuators B, 122 (2007) 659.
[3] L. Wang, J. Bai, X. Bo, X. Zhang, L. Guo,Talanta,83 (2011) 1386.
[4] J. Wang, Chem.Rev,108 (2008) 814.
[5] K. Mohammad Ali, Sh. Sedigheh, J. Of Applied Research in Chemistry, 2 (1395) 63, in Persian.
]6[ A. Rasooly, k.E.Herolds, Biosensors&bio detection, Vol 1. Optical-Based Detectors.
[7] A.P. Periasamy, y.J. Chang, S.M, Chen, Bioelectrochemistry, 80 (2011) 114.
[8] A. Vahid, J. Of Applied Chemistry, 40 (1395) 9, in Persian.
[9] N. Maryam, B. Majede, L. S. Afsaneh, K. Fatemeh, Kh. Mohammad Ali, K. . Hassan, J. Of Applied Chemistry, 25 (1391) 69, in Persian.
[10] K. Sarvenaz, Kh. Mohammad Ali, K. M. Hassan, J. Of Applied Chemistry, 44 (1396) 69, in Persian.
]11 [P.R. Bandaru,Journal of Nanoscience and Nanotechnology,7 (2007) 1239.
]12[ Ciszewski, I, Milczarek, G, Lewandowska, B, Krutowski, K, Electroanalysis 15 (2003) 518.
]13[ Y. Xiao, C. Guo, C. M. Li, Y.  Li, J. Zhang, R. Xue, S. Zhang, AnalyticalBiochemistry 371(2007) 229.
]14[ S.Palys, A. Bokuna, J. Rogalski, Electrochimica Acta 52 (2007) 7075.
]15[ J. Wang, M. Musameh, Y. Lin, J. Am. Chem 125 (2003) 2408.
]16[ M. Zhang, A. Smith W. Gorski, Anal.Chem, 76 (2004) 5045.
]17[ I. Iwuoha, D. S. Villaverde, N. P. Garcia, M. R. Smyth,  J. M. Pingarron, Biosens and Bioelectron, 12 (1997) 749.
]18[ J. C. Vidal, E. García and J. R. Castillo., Anal. Chim.Acta, 385 (1999) 213.
]19[ H. K. Ortmeye,  B.C.Hansen,  Diabetologia 37 (1994) 127.
]20[ R. S. Yalow, S.A.Noorbakhsh, E. Sharili, A. Semnani, Biosensors and Bioelectronics 24 (2008) 792.
]21[ Y. Luo, K.Hung, AnalyticaChemicaActa,64 (2005)553.
]22[ J. Zsuga, K. Tory, L. Jszlits, A. bajza,BiochemBiophysMethods 61 (2004) 253.
]23[ R. Chakrabarty, S. J. Bora, B. K. Das, Inorg. Chem 46 (2007) 9450.
]24[ S. Durmus, A. Atahan, M. Zangin, SpectrochimicaActa Part A: Molecular and Biomolecular spectroscopy 84 (2011) 1.
[25] K. Mohhamad ali, R. saeedeh, J. Of Applied Chemistry, 44 (1396) 9, in Persian.
[26] K. J. Lee, l. Yoon, Sh. S. Lee, B. Y. Lee, Bull. Korean Chem. Soc. 23 (2002) 399.
[27] T.F. Guarr, F.C. Anson, J. Phys. Chem., 91 (1987) 4037.